page 1 / 4 f/gb s/tri/SGT967760E/b/30/07/2014 relais statique triphas three phase solid state relays entraxe 47,5mm /47.5mm mounting SGT967760E output 24 to 600 vac 3 x 75 arms input 10-30vac all technical caracteristics are subject to change without previous notice. caractristiques sujettes modifications sans pravis. celduc ? ? ? ? r e l a i s proud to serve you caractristiques gnrales / general characteristics paramtre / parameter poids/ weight conditions symbol typ. 370 unit g plage de temprature de stockage / storage temperature range plage de temprature de fonctionnement/ operating temperature range -40 / +100 -40 / +100 c c ? relais statique synchrone triphas adapt aux charges rsistives. three phase zerocross solid state relay designed for resistive loads. ? sortie thyristors hautes performances technologie tms 2 (*) permettant une longue dure de vie : 24 600vac 75a. i 2 t > 5000a 2 s back to back thyristors on output with tms 2 technology(*) for a long lifetime expectancy: 24 to 600vac 75a . i 2 t > 5000a 2 s ? tension de commande 10 - 30vac led de visualisation sur l'entre de couleur verte. c ontrol range: 10-30vac . green led visualization on the input. circuit quivalent/ equivalent circuit : r s t resistive inductive lo r s t application typique / typical application : caractristiques de commande ( 20c) / control characteristics (at 20c) paramtre / parameter symbol min ac/dc nom max unit tension de commande / control voltage courant de commande / control current (@ uc ) tension de relachement/ release voltage rsistance interne / input internal resistor fig.1 uc ic 10 11 uc off rc 4 30 55 400 v ma v tension inverse / reverse voltage caractristiques d'entre-sortie ( 20c) / input-output characteristics (at 20c) isolement entre-sortie/ input-output isolation @500m isolement sortie-semelle/ output-case isolation @500m urv ui ui tension assigne isolement/ rated impulse voltage uimp 4000 3300 v vrms vrms 4000 v 0 5 10 15 20 25 30 0 0 10 20 30 40 50 60 70 0 uc(v) ic (ma) fig. 1 :caractristique d'entre / control characteristic
page 2 / 4 f/gb caractristiques thermiques / thermal curves : s/tri/SGT967760E/b/30/07/2014 caractristiques de sortie / output characteristics (at 25c) paramtre / parameter plage de tension utilisation / operating voltage range conditions symbol ue min 24 typ. 400 max 600 unit v rms tension de crte / peak voltage niveau de synchronisme / zero cross level tension minimum amor?age / latching voltage courant nominal / nominal current (ac-51) up usync ie nom ua ie ac-51 1200 10 75 35 v v 90 v a rms courant surcharge / non repetitive overload current chute directe l'tat passant / on state voltage drop rsistance dynamique / on state dynamic resistance puissance dissipe (max) / output power dissipation (max value) tp=10ms (fig. 3) @ 25c itsm vt rt pd rsistance thermique jonction/semelle thermal resistance between junction to case courant de fuite l'tat bloqu / off state leakage current courant minimum de charge / minimum load current temps de fermeture / turn on time @ue typ, 50hz rthj/c ilk @ue typ, 50hz iemin ton max 1100 1200 3x(0,9x1xie + 0,0045 x ie 2 ) 1 a v 4,5 m w 0,4 5 1 k/w ma 30 ma ms temps d'ouverture / turn off time frquence utilisation / operating frequency range dv/dt l'tat bloqu / off state dv/dt di/dt max / maximum di/dt non repetitive @ue typ, 50hz f mains toff max f dv/dt di/dt i 2 t (<10ms) immunit / conducted immunity level immunit / conducted immunity level protection court-circuit / short circuit protection iec/en61000-4-4 (bursts) i 2 t iec/en61000-4-5 (surge) type 2 example 0,1 50-60 500 30 800 ms hz 50 v/s a/s 6000 7200 2kv criterion b 2kv criterion a with external vdr fuse mersen grc80a a 2 s r e l a i s www.celduc.com celduc ? ? ? ? 5, rue ampre bp30004 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france tl. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : tl. +33 (0) 4 77 53 90 19
page 3 / 4 f/gb s/tri/SGT967760E/b30/07/2014 fig 3 : courants de surcharges / overload currents ? > warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. always use in conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable insulation in the ev ent of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...). 1 -itsm non rptitif sans tension rapplique est donn pour la dtermination des protections. 1 - no repetitive itsm is given without voltage reapplied . this curve is used to define the protection (fuses). 2 -itsm rptitif est donn pour des surcharges de courant (tj initiale=70c). attention : la rptition de ces surcharges de courant diminue la dure de vie du relais. 2 - repetitive itsm is given for inrush current with initial tj = 70c. in normal operation , this curve musn't be exceeded. be careful, the repetition of the surge current decreases the life expectancy of the ssr. ? > attention ! les relais semi-conducteurs ne procurent pas d'isolation galvanique entre le rseau et la charge. ils doivent tre utilis s associs un disjoncteur avec proprit de sectionnement ou similaire, afin d'assurer un sectionnement fiable en amont de la l igne dans l'hypothse d'une dfaillance et pour tous les cas o le relais doit tre isol du rseau (maintenance ; non utilisation sur un e longue dure...). avec capot 1k199000 with transparent cover 1k199000 dimensions r e l a i s www.celduc.com celduc ? ? ? ? 5, rue ampre bp30004 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france tl. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : tl. +33 (0) 4 77 53 90 19
page 4 /4 f/gb s/tri/SGT967760E/b/30/07/2014 sgt he raccordement d'entre / control wiring nombre de fils / number of wires modle de tournevis / screwdriver type couple de serrage recommand fil rigide (sans embout) solid (no ferrule) 0,75 ... 2,5 mm 2 awg18....awg14 fil multibrins (avec embout) fine stranded (with ferrule) fil rigide (sans embout) solid (no ferrule) 0,75 ... 2,5 mm 2 awg18....awg14 0,75 ... 2,5 mm 2 awg18....awg14 fil multibrins (avec embout) fine stranded (with ferrule) 0,75 ... 2,5 mm 2 awg18....awg14 pozidriv 2 m4 n.m 1,2 okpac ? raccordement de puissance / power wiring 1 nombre de fils / number of wires 2 modle de tournevis / screwdriver type couple de serrage recommand recommended torque fil rigide (sans embout) solid (no ferrule) 1,5 ... 10 mm 2 awg16....awg8 fil multibrins (avec embout) fine stranded (with ferrule) fil rigide (sans embout) solid (no ferrule) 1,5 ... 6 mm 2 awg16....awg10 1,5 ... 10 mm 2 awg16....awg8 fil multibrins (avec embout) fine stranded (with ferrule) 1,5 ... 6 mm 2 awg16....awg10 pozidriv 2 m5 n.m 2 puissance avec cosses / power with ring terminals. w max = 12,6mm 16 mm 2 (awg6) 25 mm 2 (awg4) 35mm 2 (awg2 /awg3) 50mm 2 (awg0 /awg1) m5 power connection m4 control connection nouvelles bornes avec rondelles freins new terminals with washers terminals r e l a i s www.celduc.com celduc ? ? ? ? 5, rue ampre bp30004 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france tl. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : tl. +33 (0) 4 77 53 90 19
|